Guide · Walk-On Rooflights · 8 min read

Walk-On Rooflight Load Ratings Explained

A load rating tells you how much weight a walk-on unit is built to carry, and in what way that weight arrives. A rating that suits a landing is not automatically right for a terrace. This guide explains the figures in plain terms, so the numbers on a quote make sense before you sign anything.

What the rating is actually telling you

Any glass floor panel in a roof or ceiling carries a stated load. On a data sheet it appears as a number, usually in kilonewtons per square metre (kN/m²) for weight spread across the panel, and in kilonewtons (kN) for weight concentrated on a small spot. Those two figures answer two different questions, and a unit is only suitable if it answers both for the way you will use it.

The rating belongs to the whole assembly, not just the glass. The panes, the interlayers that bond them, the frame, the seating and the structure underneath all take part. Change one of those and the stated figure no longer applies. That is why a walk-on unit from one maker cannot be dropped into another maker's kerb and keep its paperwork.

The types we fit are set out on the walk-on rooflight installation hub. Here the aim is narrower: to help you read the load line on a quote and ask sensible questions about it.

Spread loads and point loads

Picture two ways of standing on a pane. In the first you walk across it in socks. Your weight passes through the glass in small, fairly even steps. In the second someone drags a heavy plant pot across it on a metal base, or a ladder foot lands on one spot. The total weight may be smaller, yet it presses on a tiny area. Glass handles the first far more easily than the second.

Specifiers therefore state both loads. A spread load is the weight shared across the panel. A point load is the weight on a small, defined footprint. Impact is a third thing again: something dropped, or a person stepping down hard, rather than a steady weight.

Load typeWhat it looks likeWhere it matters
SpreadPeople standing or walkingLandings, hallways
PointFurniture feet, a ladder, a planterTerraces, plant areas
ImpactA dropped tool, a heavy stepAnywhere used for work

When two quotes carry different load lines, check which of the three each one speaks to. A figure for spread load alone says little about a terrace with a table and chairs.

Where the figure comes from

A load figure is not a guess. It comes from a design calculation and, for proprietary units, from testing by the maker. The glass is designed as a structural element, which is a different job from glazing a window. The designer looks at the span, the support along the edges, how thick and how many the panes are, and how long the load might stay in place.

The span matters most. A narrow pane supported on all four sides behaves very differently from a long one supported on two. That is why a maker's table gives a rating for each size, and why you cannot assume that a bigger unit has the same figure as a smaller one in the same range.

Our guide to walk-on rooflight glass thickness goes into how the layers are built up, and why the number of panes is a result of the loading, not a choice made separately.

Matching a rating to the place

The sensible way to choose is to start with the use, not the number. Think about who will walk there, what might be carried across, and whether furniture will stand on it.

  • Occasional foot traffic a person crossing now and then, such as a hallway panel over a basement
  • Regular foot traffic daily use, as with a landing or a bridge between rooms
  • Furnished area chairs, tables or planters standing on the panel
  • Maintenance access a panel stepped on by someone carrying tools

A panel in a ground-floor hall that lights a basement sits at the quieter end. A glazed landing in a loft conversion is walked on daily. A roof terrace outside a first-floor room may hold a table and chairs for a dinner, and that puts it among the heavier uses; that case has its own guide on terrace panels.

A floor light that doubles as a path to a plant room, where someone may kneel with a toolbox, deserves a stricter look than one that is simply stepped across. Say so at the survey, because it changes the question we put to the maker.

Households, not crowds

The design must also consider crowds. A panel in a hallway that a family uses is nothing like a panel in a shop or an office. Our work is for homes, and we size the loads to a household, then say clearly what that assumes.

It helps to picture the busiest day the panel will see. A birthday party with a dozen people on a first-floor terrace is a different event from a quiet evening with two chairs. If you host often, tell us. The rating we ask the maker to confirm should cover the busy day, not the average one, and a short conversation at the survey is far cheaper than discovering the gap later.

Equally, a panel over a basement stairwell that nobody stands on for more than a second needs no more than the household figure. Over-specifying adds weight, cost and sometimes a deeper kerb, so the aim is a fit between the figure and the use rather than the biggest number on the sheet.

The structure underneath

A strong pane on a weak kerb is still a weak floor. Whatever the glass carries is handed on to the frame, then to the kerb or upstand, and finally to the roof or floor structure. Each hand-over has to be sound.

In a flat roof that means timber joists, a steel beam or a concrete slab, depending on the house. A Victorian terrace with a lean-to or kitchen at the back may have a roof older than it looks, with joists notched years ago for pipes. A 1930s semi with a later flat-topped garage conversion has joists sized for a lighter job. A newer estate house keeps whatever spacing the original design set. Neither is a problem. Both need looking at before a heavy unit is specified.

A walk-on glass panel being bedded onto its kerb on a flat roof
A walk-on panel set into a flat roof on a purpose-built kerb, with the frame bedded to carry the weight into the structure.

This is why we do not quote a walk-on unit from a photograph. The survey checks the joists or slab, the build-up above them, and the height of the kerb. If the structure needs strengthening, a structural engineer sets out what is required, and the quote shows that work separately so nothing is hidden.

New openings also bring Building Regulations into play, because cutting a hole in a roof or floor is building work. Our guide to walk-on rooflights and Building Regulations explains what that involves.

Glass, interlayers and surface

Every walk-on build is laminated: panes stacked and bonded with tough interlayers so that, if the top layer is damaged, the layers below keep carrying the load and the panel stays in place. That is the design principle behind every walk-on unit, and it is why the cut edge of one looks like a stack.

The top layer is usually a sacrificial one, there to take scuffs and wear. Below it sit the structural layers that do the heavy lifting. Toughened or heat-strengthened glass is used for some of these, which resists load far better than ordinary annealed glass of the same thickness.

A walk-on panel can be walked on in any footwear, on any day, in any weather.

The structure carries the weight, but the surface needs thought. Wet leaves, grit, and some soles make a panel slippery, which is a separate question from strength. Our page on walk-on rooflight slip resistance deals with it.

It is also sensible to treat the glass as a floor that wears. Grit from shoes scratches the top layer over the years, and a replaceable top pane means the panel can be refreshed without disturbing the structural layers below.

Questions to put to any supplier

Whoever supplies your unit, five plain questions show if the load line on the quote was thought through. Keep the answers in writing alongside the quote.

Do not worry about sounding technical. These are the questions an engineer would ask, and a decent supplier expects them. If the answers come back as brochure language rather than figures, treat that as information about the quote.

  1. What spread load is the unit designed for, at the size being quoted?
  2. What point load, and over what footprint?
  3. Does the figure cover the frame and kerb as supplied, or only the glass?
  4. What does the unit assume about the structure under it?
  5. Which layer is the sacrificial top pane, and how is it replaced?

A supplier who hesitates on any of these has not finished the design. A good answer names the size, the supporting structure and the assumed use in one go.

If you are comparing a walk-on unit with a plain fixed one for the same opening, the walk-on rooflight cost guide shows what the extra layers and frame add to the price, and our costs page sets typical UK ranges for rooflights as a whole.

What we do at the survey

Our free survey looks at the use first. We ask who will walk there, whether furniture will stand on it and what sits underneath. We then check the roof or floor structure, the kerb or opening and the access for lifting a heavy unit into place. Glass of this kind is heavy, so getting it to the roof matters as much as the design.

The quote comes in writing, itemised, and asks nothing of you. It names the load assumptions the unit is built to, so you can compare like with like. Any structural work shows as its own line. Where a new opening is needed, we handle the Building Control notification, and a 10-year workmanship guarantee stands behind the finished job, which the guarantee page explains.

The day's work is planned so the roof is weathertight by the evening and floors are protected. If you would like a view on whether an opening unit suits the same space, our fresh air rooflights page shows how we think about it, and the rest of this series is gathered on the walk-on rooflight hub.

Load rating questions that come up before a walk-on order

Does a walk-on rooflight rating cover a person carrying something heavy?

The rating is set for a stated use, and carrying a heavy item adds to the load at the step. If someone will cross the panel with a load, say so at the survey so the point-load line can be checked against it.

Can an existing fixed rooflight be made walk-on later?

No. A walk-on unit is a different assembly, with thicker laminated glass, a stronger frame and a purpose-built kerb. The existing unit would be replaced, and the structure checked first.

Who signs off the load figure on my unit?

The maker supplies the design figures for the unit, and a structural engineer confirms the structure under it where that is in question. Both go with the quote so you can see the basis for the number.